Site / Tool Transformers

Transformers & Inductors, Site / Tool Transformers: 19 item(s) were found using the search criteria

  • Extended Range: No
  • Category ID: 717

Set Descending Direction

19 Item(s)

per page
Product List
Image Part Number Description Manufacturer Stock Level Price
(exc. VAT)
Purchase RoHS Extended
Range
Datasheet
Tough CM10002 CM10002 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 1000VA, continuous rating = 500VA, voltage input = 230V, output = 110V, 2x16A sockets. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 2

MOQ: 1

  1. 1+ £52.32
CM10002 Datasheet
10kVA (continuous rating) CM10K16 CM10K16 10kVA (continuous rating), 230V input, 110V Step-down single-phase transformer with 110V industrial 4x 16A & 2x 32A CTE (centre tap earthed) outputs. For the operation of power tools and other construction site equipment. Each pair of 16A sockets are protected by a single 20A DP MCB, each 32A socket is protected by a 32A DP MCB. Featuring heavy duty sheet steel enclosure to IP22, manufactured generally to BS4363, output sockets to BS EN 60309 / IEC 60309 (Previously BS4343), and M5 Stud input terminals to accept cabling. Made in UK. NOTE: This item is made to order.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Awaiting delivery.

MOQ: 1

  1. 1+ £411.83
CM10K16 Datasheet
10kVA (continuous rating) CM10K36 CM10K36 10kVA (continuous rating), 415V input, 110V Step-down three-phase transformer with 110V industrial 4x 16A & 2x 32A CTE (centre tap earthed) outputs for the operation of power tools and other construction site equipment. Each pair of 16A sockets is protected by a single 20A DP MCB, each 32A socket is protected by a 32A DP MCB. Featuring heavy duty sheet steel enclosure to IP23, manufactured generally to BS4363, output sockets to BS EN 60309 / IEC 60309 (Previously BS4343), and M5 Stud input terminals to accept cabling. Made in UK. NOTE: This item is made to oder.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Awaiting delivery.

MOQ: 1

  1. 1+ £476.58
CM10K36 Datasheet
A 1.5kVA (intermittent rated) CM1500/WM0 CM1500/WM0 A 1.5kVA (intermittent rated), 750VA (continuous rated), 230V input, 110V CTE output wall or floor mountable step-down transformer with a painted metal enclosure. Designed with hard-wired internal terminals on the inputs and outputs. Rated IP22 for indoor use. The unit includes re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 3

MOQ: 1

  1. 1+ £184.64
CM1500/WM0 Datasheet
A 1.5kVA (intermittent rated) CM1500/WM2 CM1500/WM2 A 1.5kVA (intermittent rated), 750VA (continuous rated), wall or floor mountable step-down transformer, with a 230V internally hard-wired input, and 2x Yellow 16A, 110V CTE outputs (BS EN 60309). Housed in a painted metal enclosure. Rated IP22 for indoor use. The unit includes a re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 9

MOQ: 1

  1. 1+ £102.11
CM1500/WM2 Datasheet
Tough CM15002 CM15002 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 1500VA, continuous rating = 750VA, voltage input = 230V, output = 110V, 2x16A sockets. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 5

MOQ: 1

  1. 1+ £52.50
CM15002 Datasheet
Tough CM22502 CM22502 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 2250VA, continuous rating = 1250VA, voltage input = 230V, output = 110V, 2x16A sockets. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 4

MOQ: 1

  1. 1+ £52.50
CM22502 Datasheet
A 2kVA (intermittent rated) CM2250WM2/110/24 CM2250WM2/110/24 A 2kVA (intermittent rated), 1.2kVA (110V) & 0.2kVA (24V) (continuous rated), wall or floor mountable step-down transformer, with a 230V internally hard-wired input, and 1x Yellow 16A, 110V CTE and 1x Purple 16A, 24V output (BS EN 60309). Housed in a painted metal enclosure. Rated IP22 for indoor use. The unit includes a re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 6

MOQ: 1

  1. 1+ £134.15
CM2250WM2/110/24 Datasheet
A 3.3kVA (intermittent rated) CM3300/WM0 CM3300/WM0 A 3.3kVA (intermittent rated), 1650VA (continuous rated), 230V input, 110V CTE output wall or floor mountable step-down transformer with a painted metal enclosure. Designed with hard-wired internal terminals on the inputs and outputs. Rated IP22 for indoor use. The unit includes re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Awaiting delivery.

MOQ: 1

  1. 1+ £115.26
CM3300/WM0 Datasheet
A 3.3kVA (intermittent rated) CM3300/WM2 CM3300/WM2 A 3.3kVA (intermittent rated), 1650VA (continuous rated), wall or floor mountable step-down transformer, with a 230V internally hard-wired input, and 2x Yellow 16A, 110V CTE outputs (BSEN 60309). Housed in a painted metal enclosure. Rated IP22 for indoor use. The unit includes a re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 4

MOQ: 1

  1. 1+ £133.56
CM3300/WM2 Datasheet
Tough CM33001 CM33001 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 3300VA, continuous rating = 1650VA, voltage input = 230V, output = 110V, 1x32A socket. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output socket to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 3

MOQ: 1

  1. 1+ £62.22
CM33001 Datasheet
Tough CM33002 CM33002 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 3300VA, continuous rating = 1650VA, voltage input = 230V, output = 110V, 2x16A sockets. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 5

MOQ: 1

  1. 1+ £55.39
CM33002 Datasheet
A 5kVA (intermittent rated) CM5000/WM0 CM5000/WM0 A 5kVA (intermittent rated), 3kVA (continuous rated), 230V input, 110V CTE output wall or floor mountable step-down transformer with a painted metal enclosure. Designed with hard-wired internal terminals on the inputs and outputs. Rated IP22 for indoor use. The unit includes re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Awaiting delivery.

MOQ: 1

  1. 1+ £299.18
CM5000/WM0 Datasheet
A 5kVA (intermittent rated) CM5000/WM4 CM5000/WM4 A 5kVA (intermittent rated), 3kVA (continuous rated), wall or floor mountable step-down transformer, with a 230V internally hard-wired input, and 4x Yellow 16A, 110V CTE outputs (BS EN 60309). Housed in a painted metal enclosure. Rated IP22 for indoor use. The unit includes a re-settable thermal cut-out switch to prevent overheating. Note: The intermittent rating is the rating when operated at maximum load for a half-hour duration. Made in UK.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 1

MOQ: 1

  1. 1+ £284.42
CM5000/WM4 Datasheet
Tough CM50003 CM50003 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 5000VA, continuous rating = 2500VA, voltage input = 230V, output = 110V, 2x16A and 1x32A sockets. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343). Supplied with 2m input mains lead - NO mains plug fitted. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 4

MOQ: 1

  1. 1+ £204.29
  2. 2+ £175.71
  3. 4+ £161.43
CM50003 Datasheet
5kVA (continuous rating) CM5K15 CM5K15 5kVA (continuous rating), 230V input, 110V Step-down single-phase transformer with 110V industrial 4x 16A, 1x 32A CTE (centre tap earthed) outputs. For the operation of power tools and other construction site equipment. Each pair of 16A sockets are protected by a single 20A DP MCB, each 32A socket is protected by a 32A DP MCB. Featuring heavy duty sheet steel enclosure to IP23, manufactured generally to BS4363, output sockets to BS EN 60309 / IEC 60309 (Previously BS4343), and M5 Stud input terminals to accept cabling. Made in UK. NOTE : Made to order
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Awaiting delivery.

MOQ: 1

  1. 1+ £292.62
CM5K15 Datasheet
Tough CM7501 CM7501 Tough, UK made 110V portable tool / site safety transformer for construction industry power tool, lighting and machinery applications. Intermittent tool rating = 750VA, continuous rating = 375VA, voltage input = 230V, output = 110V, 1x16A socket. Manufactured to BSEN 61558, with thermal overload protection, glass reinforced polyester (GRP) case providing ingress protection to IP44. Output socket to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 10

MOQ: 1

  1. 1+ £51.66
CM7501 Datasheet
Tough CMH1200/110 CMH1200/110 Tough, compact UK made 110V portable tool / site safety transformer, in IP22 metal housing, with shoulder carry strap. For use with construction industry power tools and lighting. Intermittent tool rating = 1200VA, continuous rating = 600VA, voltage input = 230V, output = 110V, 1x16A socket. Manufactured to BSEN 61558, with thermal overload protection. Output socket to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead fitted with BS1363 UK mains plug. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 9

MOQ: 1

  1. 1+ £110.32
CMH1200/110 Datasheet
Tough CMHT3 CMHT3 Tough, UK made 110V portable tool / site safety transformer, in IP22 metal housing, with carry handle. For use with construction industry power tools, lighting and other equipment. Continuous rating = 3000VA, voltage input = 230V, output = 110V, 1x32A socket. Manufactured to BSEN 61558, with thermal overload protection. Output socket to BS EN 60309 / IEC 60309 (Previously BS4343). 2m input mains lead withbare ends. Size: 290x200x240mm. N.B. Intermittent tool rating is the maximum rating for operating load at 25% duty cycle, i.e. 5 mins on / 15 mins off.
Special Instructions: Due to inherent high in-rush currents at switch-on, this unit requires a suitably rated anti-surge supply fuse. Miniature Circuit Breakers (MCB's) protecting sockets should have a type C or D tripping characteristic.
Carroll & Meynell

Available: 10

MOQ: 1

  1. 1+ £159.84
CMHT3 Datasheet

Set Descending Direction

19 Item(s)

per page